1. Battery Specifications
| Parameter | Value |
|---|---|
| Type | Rechargeable Li-ion |
| Configuration | 3S1P |
| Maximum Voltage | 12.6 VDC |
| Nominal Voltage | 10.8 VDC |
| Nominal Capacity | 3.4 Ah / 36.72 Wh |
| Protection Circuit | Charge, Discharge, Overvoltage |
| Maximum Discharge Current (peak) | 9.4 A |
| Maximum Continuous Discharge | 6.4 A / 2C |
| Continuous Discharge | 640 mA / 0.2C |
| Recommended Standard Charge | 1.2 A |
| Maximum Current Permitted | 3.2 A |
| Rated Voltage of Charger | Must not exceed 12.6 V |
| Weight | 200 g approx / 7.05 oz |
2. Battery Charge Indicator
The battery status is indicated by a 14-segment eInk display on the front:
| Display State | Meaning |
|---|---|
| All 14 segments black | Battery fully charged |
| Segments turn white as battery discharges | Battery discharging |
| All 14 segments white | Battery completely discharged |
The display requires no power to maintain the visible reading.
3. Temperature Ranges
| Condition | Temperature Range |
|---|---|
| Charge Temperature | 0°C to 45°C / 32°F to 113°F |
| Discharge Temperature | -20°C to 50°C / -4°F to 122°F |
| Storage Temperature (Idle) | -20°C to 60°C / -4°F to 140°F |
| Heat Protection | Thermal at 70°C / 158°F |
4. Discharge Performance
| Condition | Rate | Relative Capacity |
|---|---|---|
| Continuous discharge | 640 mA / 0.2C | ~100% at 25°C |
| Maximum continuous discharge | 6.4 A / 2C | ~95% at 25°C |
| Maximum discharge peak | 9.4 A | - |
5. Charging Information
| Parameter | Value |
|---|---|
| Charging time | 3 hours (using Elebia charger) |
| Recommended standard charge | 1.2 A |
| Maximum current permitted | 3.2 A |
| Rated voltage of charger | Must not exceed 12.6 V |
Note: Time to charge may vary depending on the chargers being used and temperature, among other variables.
6. Storage Recommendations
- For long term storage, charge battery to 50% of its capacity
- Recharge every 3 months
- Check charge status every 3 months
- Do NOT store battery discharged (may cause irreversible damage)
- Store in a clean, dry area away from water or wet environments
7. Important Warnings and Cautions
- Never short circuit the terminals
- Do not expose the battery to heat or a fire source
- Keep battery clean and dry, away from water or wet environments
- Do not manipulate the battery (warranty becomes invalid if manipulated)
- Do not use the battery if there are any impacts, dents, etc.
Low voltage check: If a battery loses its charge and remains uncharged for a long period, check voltage between terminals. Voltage must be more than 7.5 V. If voltage is under this value, do not attempt to charge the battery and send it to Elebia technical service.
8. Warranty
| Component | Warranty Period |
|---|---|
| EVO2-1700 Battery | 6 months |
9. Recommendation
Use chargers recommended by the manufacturer to charge the batteries.
For further inquiries or assistance, please contact our customer support team. We are here to help!